Date: 24 November 2026
With the Government's call for evidence on Part K continuing, the Glass and Glazing Federation (GGF) is highlighting the importance of understanding safety glazing requirements, barrier loading and the performance of complete window and door assemblies.
Building Regulations remain a significant focus for the glass and glazing industry, particularly following the Chancellor's recent announcement that changes during this Parliament would be limited to those relating to safety.
The announcement prompted questions across the sector about the future of planned regulatory developments, including the call for evidence on Part K.
Kevin Jones, Technical Director at the GGF, confirms that the Federation has sought clarification from Government and that the Part K call for evidence is progressing.
“The call for evidence on Part K is still going ahead, and we're working on that with the Glazing Technical Groups and the Consultation Response Group.”
The process will help inform future considerations around the regulations, while existing requirements remain important for businesses involved in specifying, manufacturing and installing glazing products.
Understanding the requirements of Part K
Part K of the Building Regulations addresses protection from falling, collision and impact, making it particularly relevant to the specification and installation of glazing.
For the glass and glazing industry, one of its key considerations is the use of safety glass in critical locations.
“Part K is tied directly into safety of glass and the location,” says Kevin. “It talks about critical locations, so doors at ground floor, for example, or areas where you have glass below a certain level. It's required to be safety glass because there's an increased likelihood of impact on that glass.”
Depending on the application and relevant requirements, suitable glazing specifications may include toughened or laminated safety glass.
Part K also has important implications for windows and doors that perform a protective barrier function, particularly in new-build and commercial projects where large areas of glazing and floor-to-ceiling designs are increasingly common.
In certain situations, a window or glazed door may be required to provide protection against a fall, particularly where there is a significant change in level beyond the glazing.
This can also arise where an originally specified Juliet balcony or separate protective barrier is removed or altered during the design process.
In these circumstances, the glazing assembly may need to fulfil the barrier function itself, creating additional performance requirements.
Why the complete assembly matters
A particularly important consideration is the need to assess the performance of the complete glazing assembly.
Where windows and doors are required to resist barrier loading, the glass specification represents one element of the overall design. The framing system, structural couplers, fixings and supporting materials must also be capable of withstanding the relevant loads.
Kevin highlights the importance of considering every component:
“There's a requirement under the standard as well that it's the whole assembly that we're looking at. We're talking about the fixings, the material that they're fixed into as well. That whole assembly needs to be able to withstand the load.”
This is particularly relevant to large glazed areas, upper-floor windows and installations where failure could create a risk of falling from height.
Understanding these requirements during the specification and design stages can help businesses identify appropriate solutions and avoid potential compliance issues later in a project.
Supporting members with technical expertise
The GGF provides members with access to experienced technical specialists who can help them navigate complex requirements and make informed decisions about their glazing projects.
Through its Technical Team, the Federation supports members seeking clarification on Part K and its implications for individual projects.
“We are able to talk members through the legislation so that they're clear on the understanding of what the actual requirements are, and then we can talk through with them the design of the products to make sure that they're hitting those compliance requirements,” says Kevin.
The GGF also offers structural glass calculation services, helping businesses assess glass specifications for particular applications, including glazed barriers, balconies and other specialist installations.
Kevin adds: “We also have the ability to do structural calculations on glass as well, so we can guide you in terms of what the glass specification needs to be for an individual situation.”
Depending on the project's requirements, the Technical Team can provide initial guidance or a detailed structural calculation report containing project-specific specification information.
GGF members seeking advice on Part K or structural glass calculations can contact the Technical Team at technical@ggf.org.uk.
Keeping safety at the centre of specification
As the industry continues to engage with the Part K call for evidence, understanding existing safety requirements remains essential.
With glazing increasingly incorporated into architectural designs that combine aesthetics, accessibility and structural performance, careful consideration of the complete assembly is vital.
The GGF will continue working with its technical groups and members to contribute industry expertise to ongoing discussions surrounding Part K, while providing practical support to help businesses understand and meet their technical obligations.
For more information about the GGF and how it supports businesses across the glass and glazing industry, visit www.ggf.org.uk or email membership@ggf.org.uk.
Add new comment